Modular Equipment Enclosures & Machine Enclosures
Prefabricated protective enclosures engineered to house, protect, and isolate industrial equipment — from electrical switchgear and compressors to CNC machines and robotic cells. Custom-built to your exact specs and delivered ready to install.
Call (800) 326-4403 or Email Sales@MH-USA.com

What Is a Modular Equipment Enclosure?
A modular equipment enclosure is a prefabricated, engineered structure designed to house, protect, and isolate industrial equipment from environmental conditions, physical damage, contamination, and unauthorized access. Unlike field-built enclosures that require on-site welding, framing, and finishing, modular enclosures are manufactured in a controlled factory environment to precise specifications — then delivered and installed at your facility in a fraction of the time.
Material Handling USA designs and delivers equipment enclosures for applications ranging from electrical switchgear and transformer housings to compressor buildings, pump stations, CNC machine enclosures, robotic workcell cages, and climate-controlled instrument shelters. Every enclosure is engineered to meet the specific environmental, electrical, and structural requirements of the equipment it protects — including NEMA ratings, temperature control, ventilation, fire suppression, and seismic specifications.

Equipment Enclosure Types & Applications
We engineer enclosures for virtually any equipment protection requirement — from simple weather covers to fully climate-controlled, code-compliant structures.
Electrical Equipment Enclosures
Protect switchgear, transformers, motor control centers (MCCs), and distribution panels from weather, dust, and unauthorized access. Available with NEMA 3R, 4, or 12 ratings, UL 508A-compliant internal wiring, and arc-flash rated ventilation systems.
Compressor & Pump Houses
Sound-attenuating enclosures for air compressors, hydraulic power units, and pump stations. Designed with proper ventilation, noise reduction (up to STC 47), vibration isolation, and maintenance access panels for routine servicing without removing the enclosure.
CNC & Machine Enclosures
Protect precision machinery from airborne contaminants while containing coolant mist, chips, and noise. Enclosures include chip-tight sealing, integrated mist collection, LED lighting, and operator access doors with safety interlocks.
Robotic Workcell Enclosures
Safety-rated enclosures around robotic arms and automated systems with proper guarding, light curtains, access interlocks, and viewing windows. Designed to meet OSHA machine guarding standards and ANSI/RIA 15.06 robot safety requirements.
Climate-Controlled Instrument Shelters
Temperature and humidity-controlled enclosures for sensitive analytical instruments, process control equipment, and communication systems. Maintain ±2°F temperature stability with redundant HVAC and continuous environmental monitoring.
Construction & Engineering Standards

Every equipment enclosure starts with a structural steel or aluminum frame designed to support the specific loads and environmental conditions of your application. Wall and roof panels use insulated metal panels (IMPs) with R-values from R-11 to R-38 depending on climate requirements. Panel skins are available in galvanized steel, stainless steel, aluminum, or fiberglass reinforced plastic (FRP) for corrosive environments.
Foundations range from simple concrete pads to engineered steel skid bases for relocatable installations. Every enclosure is designed to meet local building codes, IBC structural requirements, and any applicable electrical codes (NEC, UL 508A, NFPA 70). For hazardous locations, we engineer enclosures to meet NEC Class I Division 1 or 2, and Class II Division 1 or 2 requirements with appropriate explosion-proof components.
Why Choose Modular Equipment Enclosures?

Need a Hazardous Location Enclosure?
We engineer equipment enclosures for NEC Class I and Class II hazardous locations — including Division 1 and Division 2 areas. Explosion-proof lighting, ventilation, electrical components, and gas detection systems are integrated into the enclosure design to meet NFPA 70 and local AHJ requirements.
Common Equipment Enclosure Configurations
Select the right configuration based on your equipment type and protection requirements.
| Application | Typical Size | Key Features | NEMA Rating | Starting Price |
|---|---|---|---|---|
| Electrical Switchgear | 10×20 to 12×40 ft | Climate control, arc-flash vent, bus duct entry | 3R / 4 | $45,000–$120,000 |
| Compressor Building | 10×12 to 16×24 ft | Sound attenuation, ventilation, vibration pads | 3R | $30,000–$75,000 |
| Instrument Shelter | 8×10 to 10×16 ft | ±2°F HVAC, UPS power, cable management | 4 / 12 | $25,000–$60,000 |
| Pump Station | 8×12 to 12×20 ft | Drainage, spill containment, maintenance access | 3R / 4X | $20,000–$55,000 |
| Generator Enclosure | 10×20 to 14×30 ft | Sound reduction, exhaust routing, fuel system | 3R | $35,000–$90,000 |
| Robotic Workcell | Custom | Safety interlocks, guarding, viewing windows | 12 | $15,000–$50,000 |
Frequently Asked Questions
Explore More Modular Building Solutions
Need a Custom Equipment Enclosure?
Get a free engineering consultation — Material Handling USA designs, builds, and installs custom equipment enclosures nationwide.
