Modular Isolation Rooms for Hospitals, Clinics and Labs

Prefabricated negative- and positive-pressure isolation rooms with anterooms, HEPA filtration and pressure monitoring — designed around your HVAC and code requirements, built off-site and installed with minimal disruption to the rest of the facility.

Finished Panel Built modular negative pressure isolation room with white wall panels, return grilles and a self-closing door

12 ACH

Typical AIIR minimum

0.01 in. wc

Min. pressure difference

Anteroom

Buffer zone option

Prefab

Fast, clean install

Shop Isolation Carts for PPE at the Door

Metro isolation carts keep gowns, gloves, masks and supplies organized outside every isolation room and anteroom. Order online, or ask us to include carts and storage in your isolation room project.

Metro FLISO3 Flexline Isolation CartFlexline Isolation CartMetro FLISO3 Flexline Isolation Cart$3,203.29View product →
Shop all isolation carts →
Metro SXRSISO Starsys Isolation CartStarsys Isolation CartMetro SXRSISO Starsys Isolation Cart$2,889.01View product →
Shop all isolation carts →
Metro MBX1030ISOB Basix Isolation CartBasix Isolation CartMetro MBX1030ISOB Basix Isolation Cart$2,909.73View product →
Shop all isolation carts →
Metro MBP0120ISO Basix Plus Isolation CartBasix Plus Isolation CartMetro MBP0120ISO Basix Plus Isolation Cart$3,037.36View product →
Shop all isolation carts →

What Is an Isolation Room?

An isolation room separates a patient, sample or process from the rest of a building to stop airborne contaminants spreading. Pressure is the key: negative-pressure rooms pull air in and exhaust it, keeping infectious particles inside; positive-pressure rooms push clean, filtered air out, keeping contaminants away from vulnerable patients.

MH-USA supplies and installs prefabricated modular isolation rooms from Panel Built, and coordinates them with casework, storage and carts. For isolation rooms inside hospitals and research labs, our laboratory design team plans the room with pass-throughs, benches and equipment.

Modular-panel hospital isolation room with patient bed, ceiling exhaust grille and self-closing door to the anteroom

Types of Isolation Rooms

US healthcare design generally recognizes airborne infection isolation rooms (AIIR) and protective environment rooms (PE), plus standard single rooms used for contact and droplet precautions. Laboratories and industry use similar pressure-controlled rooms for containment.

Choosing the right type first matters, because the pressure relationship drives everything else: the HVAC design, whether an anteroom is needed, the door hardware, the monitor and the finishes. It also decides whether a room can later be switched between uses, which many facilities now ask for after recent outbreaks.

⇩

Airborne infection isolation (AIIR)

Negative pressure. For patients with airborne diseases such as tuberculosis or measles. Air flows in from the corridor and is exhausted outdoors or through HEPA filters.

⇧

Protective environment (PE)

Positive pressure. For immunocompromised patients, such as transplant and oncology. HEPA-filtered supply air keeps contaminants out.

⇄

Combination AIIR/PE

An infectious patient who is also immunocompromised. Usually uses an anteroom to manage both pressure relationships.

▢

Standard isolation rooms

Neutral pressure single rooms with hand hygiene and PPE at the door, used for contact and droplet precautions.

⚗

Laboratory containment rooms

Negative-pressure suites for biosafety work, pharmacies and hazardous processes, often with interlocked doors and pass-throughs.

⏱

Temporary and surge rooms

Modular rooms that convert existing space quickly during outbreaks, then stay as permanent capacity or relocate.

A note on Class S, Class P and Class N

Some guidelines, notably in Australia, classify isolation rooms as Class S (standard pressure), Class P (positive pressure, protective), Class N (negative pressure, infectious) and Class Q (quarantine). In the US, design teams normally specify AIIR and PE rooms to ASHRAE 170 and the FGI Guidelines.

Room type Pressure Supply / exhaust Typical use
AIIR Negative to corridor Exhaust directly outdoors (or through HEPA where permitted) Airborne infectious patients
Protective environment (PE) Positive to corridor HEPA-filtered supply air Immunocompromised patients
Combination AIIR/PE Managed through an anteroom HEPA supply plus dedicated exhaust Infectious and immunocompromised
Standard isolation Neutral Normal patient room ventilation Contact and droplet precautions
Lab containment Negative to adjacent areas Dedicated exhaust, often HEPA Biosafety, compounding, hazardous work

Negative Pressure Isolation Room Requirements

Differential pressure gauge and monitoring panel mounted on a modular room wall

In the US, the ventilation of new and renovated AIIRs is generally designed to ASHRAE Standard 170 and the FGI Guidelines, with CDC infection-control guidance. Typical design values include:

  • At least 12 total air changes per hour (ACH), including outdoor air.
  • Room held at least 0.01 in. w.c. negative to the corridor.
  • Room air exhausted directly outdoors, not recirculated to other spaces.
  • A permanent pressure monitor with a visual indicator at the door.
  • A well-sealed room: ceiling, penetrations, door and windows.

Your engineer and AHJ set the final numbers

Requirements vary by edition of the code adopted in your state, by room type and by whether the work is new construction or renovation. MH-USA builds the room envelope to the mechanical engineer’s design and coordinates with your HVAC contractor; we don’t replace the engineer of record or the authority having jurisdiction.

Isolation room design checklist

  • Room type and pressure relationship (AIIR, PE, combination or lab containment).
  • Air change rate, outdoor air and exhaust path from the mechanical design.
  • Anteroom or no anteroom, and door interlock or self-closing hardware.
  • Sealed ceiling system, sealed penetrations and gasketed doors.
  • Pressure monitor and alarm at the entrance.
  • Hand-wash sink, PPE storage and waste at the entrance.
  • Cleanable, chemical-resistant wall and floor finishes.
  • Toilet room or patient-care equipment needs for patient rooms.
  • ICRA measures to protect the rest of the building during installation.

Anterooms: The Buffer Zone

An anteroom sits between the corridor and the isolation room. Staff put on and remove PPE there, wash hands, and pass through one door at a time, so the pressure difference holds even when a door opens.

Anterooms are required for some room types and recommended for many others. In a modular system they are simply another set of panels and doors, built at the same time as the room. Plan PPE carts, glove holders and a hand-wash sink into the space from the start.

Isolation room anteroom with hands-free sink, glove box holders and a PPE supply cart between two self-closing doors

Modular vs Conventional Construction

Installers assembling prefabricated modular wall panels to build an isolation room inside a hospital wing

Panel Built modular isolation rooms are prefabricated in the factory from wall panel systems, then shipped and assembled on site. With the panels made off-site there is far less cutting, dust and debris during installation, which keeps disruption low in an occupied hospital or lab.

Like manufacturing cleanrooms, the rooms can include HEPA filtration and UV lighting to clean the room’s air with a high rate of air exchange, and they can be reconfigured or relocated later.

Factor Modular isolation room Conventional drywall build
On-site disruption Low: panels arrive finished and assemble quickly Higher: framing, drywall, mud, sanding and paint
Dust and debris Minimal cutting and waste on site Significant, needs more containment
Schedule Fabrication runs while the site is prepared Sequential trades on site
Finishes Smooth, cleanable factory-finished panels Depends on paint and finish system
Future changes Panels can be reconfigured, expanded or relocated Demolition and rebuild
Tax treatment Often treated as equipment; ask your tax advisor Treated as building improvement

Panel Built has built modular rooms for decades, from in-plant offices to cleanrooms and isolation rooms. MH-USA is an authorized dealer: we handle layout, quoting, delivery coordination and installation, and pair the room with storage, carts and casework.

Download the Modular Isolation Rooms brochure (PDF)

Empty modular isolation room interior with white panels, sealed ceiling grid and wall grilles

What a Modular Isolation Room Includes

Every room is configured to the project, but most modular isolation rooms are built from the same set of components. Use this list to scope your project and to see what MH-USA supplies versus what your mechanical and electrical contractors provide.

▢

Wall panel system

Factory-finished modular panels with smooth, cleanable faces, sized to your room, anteroom and ceiling height.

◫

Ceiling system

Sealed or gasketed ceiling grid and panels so the room can hold its pressure difference.

🚪

Doors and hardware

Self-closing doors with vision panels, gaskets and optional interlocks between the anteroom and room.

🌬

Air handling interfaces

Openings for supply diffusers, exhaust grilles, HEPA units and ductwork, coordinated with your HVAC design.

⚠

Monitoring

Space for a differential pressure monitor and alarm at the entrance, wired by your electrician.

☘

Fit-out

Hand-wash sink location, PPE carts, glove box holders, storage and casework planned into the layout.

Where Modular Isolation Rooms Are Used

✚

Hospitals

Converting existing patient rooms or wards to AIIR or PE rooms without a long construction shutdown.

⚠

Emergency departments

Negative-pressure exam or triage rooms for patients with suspected airborne disease.

☤

Clinics and long-term care

A small number of isolation rooms for outbreaks, added inside existing buildings.

⚗

Research and testing labs

Containment rooms around biosafety cabinets and hazardous processes; see modular laboratory buildings.

⚕

Pharmacies

Negative-pressure rooms for hazardous drug compounding, coordinated with cleanroom suites.

⚙

Industry and government

Contained rooms for hazardous materials, quarantine and correctional health.

Laboratory containment suite with modular walls, interlocked door and a pass-through beside a biosafety cabinet

Isolation and containment for laboratories

In labs, a negative-pressure room around a biosafety cabinet or hazardous process works like a second barrier. These rooms often add interlocked doors, a pass-through for materials, sealed lighting and smooth floors. Our modular clean rooms page covers positive-pressure cleanrooms, and Labs USA compares hardwall vs softwall cleanrooms.

How MH-USA Delivers Your Isolation Room

MH-USA designs, supplies and installs modular rooms, storage and lab furniture nationwide. We work alongside your facility team, mechanical engineer and HVAC contractor so the room envelope, doors, finishes and fittings match the ventilation design.

1

Site review

Share floor plans, room type and photos; we confirm size, ceiling height and access.

2

Layout & quote

We draw the room, anteroom and doors and quote panels, fittings and installation.

3

Coordinate

We coordinate with your engineer and HVAC contractor on penetrations, monitors and exhaust.

4

Install

Panels are assembled on site with minimal disruption; we add carts, storage and casework.

Need isolation rooms fast?

Send your floor plan and room requirements. We’ll return a layout, a quote and a schedule.

Request a Quote Explore Modular Buildings Call (800) 326-4403

Isolation Room FAQs

What is a negative pressure isolation room?
A negative pressure isolation room, or airborne infection isolation room (AIIR), is kept at lower air pressure than the corridor so air flows in, not out. Room air is exhausted outdoors or through HEPA filters, keeping airborne pathogens contained.
What is the difference between negative and positive pressure isolation rooms?
Negative pressure rooms contain infectious patients or hazards by pulling air in. Positive pressure rooms, or protective environments, protect immunocompromised patients by pushing HEPA-filtered air out so contaminants cannot enter.
What are the requirements for a negative pressure room?
Typical US design values under ASHRAE 170 and the FGI Guidelines include at least 12 air changes per hour, at least 0.01 inches of water column negative pressure to the corridor, exhaust directly outdoors, a sealed room and a permanent pressure monitor. Your engineer and local authority confirm the exact requirements.
Does an isolation room need an anteroom?
Anterooms are required for some room types, such as combination AIIR/PE rooms, and recommended for many others. They create a buffer for putting on and removing PPE and help keep the pressure difference stable when doors open.
Are modular isolation rooms permanent?
They can be. Modular isolation rooms are built from prefabricated wall panels and can stay as permanent rooms, or be reconfigured, expanded or relocated later as needs change.
How fast can a modular isolation room be installed?
Panels are fabricated off-site while the site is prepared, and assembly on site is much faster than conventional construction with far less dust. Your schedule depends on size, HVAC work and approvals; we give a project schedule with the quote.
Do modular isolation rooms include HEPA filtration?
They can. Like manufacturing cleanrooms, modular isolation rooms can include HEPA filtration and UV lighting, coordinated with the building’s HVAC and the engineer’s ventilation design.
How do I buy an isolation room from MH-USA?
Call 800-326-4403 or request a quote with your floor plan and room requirements. We’ll design the layout, quote the room and install it, and can add isolation carts, storage and casework.

Plan Your Modular Isolation Room

Send your floor plan and requirements. We’ll design the room and anteroom, coordinate with your engineer and install it.

Headquartered in Salt Lake City, UT • Serving customers nationwide
Local service areas: Salt Lake City • Provo • Ogden • Park City • St. George • Logan • Lehi • Orem