Vidir Wire Spool Carousel Case Study: IES Residential, McKinney, Texas
How a residential electrical contractor put 39 wire bays of building wire into one 19-foot Vidir Wire Spool Carousel with measured payout at the pick opening.

Customer
IES Residential
Location
711 Tower Lane, McKinney, TX 75069 (Collin County)
Product
Vidir Wire Carousel, Model W39225-1334-06 — 13 carriers, 39 wire bays
Application
Motorized storage and measured payout of residential building wire spools
About the project
IES Residential is a residential electrical contractor — the kind of operation that wires whole subdivisions, runs a fleet of vans out of one building every morning, and buys building wire by the spool in a handful of gauges but very large quantities. Its facility at 711 Tower Lane in McKinney, Texas, north of Dallas in Collin County, is where that wire is held and staged.
Material Handling USA supplied and installed one Vidir Wire Carousel — a motorized vertical carousel whose carriers are enclosed wire bays, Model W39225-1334-06 — at the McKinney facility. The machine stands 19’3" high on an 8’9" by 6’3" footprint, carries thirteen carriers with 39 individual wire bays, and was ordered with three payout accessories: a certified wire meter slider, a wire spinner spool assembly and a wire spool lift-and-load dolly.
That accessory package is what makes this project worth studying. A residential contractor does not just store wire, it issues measured lengths to crews all day — and the meter slider is how that stops being a guess. The install is one of the projects behind our vertical storage for electrical supply and wire distribution page and part of the Vidir vertical storage line.
Project scope at a glance
The situation
Residential electrical work runs on a short list of wire types in enormous volume. That sounds easy to store until you count spools: several gauges, multiple jacket types and colors, ground wire, and enough of each to keep crews from running dry mid-week. Stored on static reel racks, that inventory takes a long wall plus the aisle in front of it, in a building where floor space is already committed to staging, material carts and van bays.
The bigger cost is the daily handling. Every crew that leaves needs a length of wire, and on a rack that means finding the right spool, getting a stand under it, spinning it by hand, guessing the length or measuring it across the floor afterwards, and lifting the partial spool back onto a pin. Multiply that by a fleet of vans leaving each morning and the wasted time is real — as is the over-pull that quietly inflates wire cost per house.
A wire carousel with measured payout changes the whole transaction. The operator calls the carrier, the machine rotates that bay to one fixed opening at working height, and the wire is measured as it comes off the spool without the spool ever leaving the machine.

What Material Handling USA supplied
Material Handling USA supplied and installed one Vidir Wire Carousel, Model W39225-1334-06: a freestanding powered carousel 19’3" high, 8’9" wide and 6’3" deep, with thirteen W39 wire-bay carriers, uprights with a 2" wire mesh front and a corrugated sheet metal back, and a front control tower.
Each carrier is divided into three wire bays — 39 bays in total — measuring 26.25" wide by 26.5" high, sized for spools up to 24" in diameter. Spools mount on wire bay rods, and the machine shipped with twenty-six 0.75" standard-duty rods and forty-four 1" heavy-duty rods, so bays can be re-cut for different spool widths as the stocked wire list changes.
Two 1.5 HP Leeson motors drive the carousel at a fixed speed, moving carriers at up to 21 feet per minute. Controls are forward/reverse push buttons at the front control tower, with a mushroom E-stop, a main power disconnect and a security keypad — the keypad matters in a building where a lot of people walk past a lot of copper. Power is 208V, three-phase, 15 amp on an isolated circuit, hooked up at the front top right corner of the machine. The tower is anchored to the slab with 5/8" HILTI KB-TZ stud anchors through 9.5" x 6" foot plates.
Three accessories were ordered with the machine. The imperial certified wire meter slider measures wire as it is drawn off at the opening. The wire spinner spool assembly rotates in its bay so cable unwinds under even tension. The wire spool lift-and-load dolly raises full spools to bay height for loading. All three are cataloged on our vertical carousel accessories and options page.
Full product specifications
Below is the published product specification for the machine installed at the McKinney facility. A carousel is a manufactured product, so these are the numbers used to confirm it would clear the ceiling, fit the space and carry the spool weights.
| Specification | Value |
|---|---|
| Model | W39225-1334-06 |
| Product type | Wire Carousel (vertical carousel) |
| Overall height | 19′ 3″ |
| Overall width | 8′ 9″ |
| Overall depth | 6′ 3″ |
| Overall weight capacity | 13,000 lbs |
| Live load capacity | 11,861 lbs |
| Carrier type | W39 wire bay |
| Total carriers | 13 |
| Total wire bays | 39 |
| Wire bay dimensions | 26.25″ W x 26.5″ H |
| Maximum spool diameter | 24″ |
| Maximum weight per carrier | 1,000 lbs |
| Average capacity per carrier | 912 lbs |
| Standard-duty wire bay rods | (26) 0.75″ rods |
| Heavy-duty wire bay rods | (44) 1″ rods |
| Drive system | (2) 1.5 HP Leeson motors |
| Electrical | 208V, 3-phase, 15 amp (isolated circuit) |
| Controls | Forward/reverse push button, front control tower |
| Drive configuration | Fixed speed |
| Control options | Mushroom E-stop, main power disconnect, security keypad |
| Max. retrieval speed | 21 ft per minute |
| Guarding | Uprights, 2″ wire mesh front, corrugated sheet metal back |
| Foot plate dimensions | 9.5″ D x 6″ W x 0.375″ H |
| Concrete anchors | 5/8″ HILTI KB-TZ stud anchor |
| Finish | VM White Textured (300-1106), machine and carriers |
| Options supplied on this project | Imperial certified wire meter slider, wire spinner spool assembly, wire spool lift and load |
| Warranty | 2 years parts and labor (manufacturer) |

Install and site requirements
The manufacturer’s order acknowledgement for this project spells out exactly what a site has to have ready, and it is worth publishing because it is the same list on every wire carousel we install.
Electrical: 208 volt, three phase, 15 amp on an isolated circuit per machine, roughed in by the site electrician in advance. An electrician has to be available part-way through installation for final hookup, because the connection point is on the front top right corner of the machine once the tower is standing.
Forklift: one 3,000–4,000 lb capacity forklift with 4 ft forks and at least 15 ft of high reach, available for unloading and erection.
Scissor lift: one 18–20 ft electric scissor lift with a maximum 32" base width — the narrow base matters because the lift has to work close to the tower.
Vidir’s installers are certified to operate forklifts and scissor lifts themselves; where site rules do not allow that, the site provides an operator for the duration. The floor has to be level and troweled smooth, at least 6" thick, so 5/8" stud anchors can hold the column loads. Our vertical storage installation services page carries the full pre-install checklist.

What the contractor gained
Wire carousel or static reel rack?
| Vidir Wire Carousel (used here) | Static wire reel rack | |
|---|---|---|
| Floor footprint | One 8’9″ x 6’3″ footprint | Runs along a wall plus a clear working aisle |
| Vertical use | Stores to 19’3″ and picks at one opening | Limited to safe manual reach |
| Bay count | 39 bays at 26.25″ x 26.5″ | As many positions as wall length allows |
| Spool handling | Spools stay on rods inside the machine | Manual lift on and off the rack |
| Payout | Certified meter slider and spinner spool at the opening | Reel stand, then measure by hand |
| Access control | Enclosed mesh, keypad on the control tower | Open rack |
| Best for | High-volume issuing from a short list of gauges | A handful of spools and low turnover |
Our wire spool carousel vs. wire reel rack comparison covers the economics, and the vertical carousel vs. traditional storage page applies the same logic to parts and supplies. For high-throughput distribution operations, the vertical storage for warehousing and logistics page covers the wider picking case.
How to specify a wire carousel
Start with the wire, not the machine. List every spool type you stock, the largest spool diameter and width, and the weight of a full spool. Those numbers set the bay size, the rod diameter and the carrier rating — here, 26.25" x 26.5" bays, spools to 24" diameter, 1,000 lbs per carrier and a mix of 0.75" and 1" rods.
Then measure the building, because the building picks the model. This platform is built in several heights on the same 8’9" x 6’3" footprint: seven carriers at 10’9" for a low-clearance warehouse, thirteen carriers at 19’3" as installed here, and W45 machines that reach 21 feet with larger bays. Confirm clear height under sprinklers and lights before anything else.
Decide the payout hardware up front. Meter sliders, spinner spools and lift-and-load dollies all mount to the same machine, but adding them later is a second freight bill. If you issue measured lengths daily, the meter slider is the accessory that pays for itself.
Compare projects before you size yours: the 7-carrier machine at an electrical contractor in Englewood, Colorado for a low-ceiling building, the 21-foot, 36-bay wire reel carousel at Tucson Electric Power for utility reels, the cable drum carousel at an electrical wholesaler for large drums, and the compact machine in a maintenance stores for a small wire list. For taller or highly variable loads compare a vertical lift module, for budget ranges start with the vertical storage cost and pricing guide, and machine details for this platform live on the Vidir Wire Carousel page. We supply and install nationwide, including the Dallas–Fort Worth metroplex.

Frequently asked questions
What is a wire spool carousel?
How many wire spools does this machine hold?
How much floor space does it use?
Can wire be measured as it comes off the spool?
What is a wire spool lift and load?
What power does a wire carousel need?
What does the site have to provide for installation?
Do you supply wire carousels to electrical contractors in Texas?
Issuing measured wire out of a reel rack?
Send us your spool list — gauges, largest spool diameter and full-spool weights — plus your clear ceiling height, and we will size a Vidir Wire Carousel with the bay layout, meter slider and installation scope your operation needs.