8′ x 10′ Modular In-Plant Office

80 square feet: the most common single-person in-plant office. Room for a full desk, a file cabinet and a guest chair, with insulated walls, a door, a window and pre-wired lighting.

Request pricing for your configuration. Call (800) 326-4403 or email Sales@MH-USA.com

Blue modular in-plant office with yellow guardrail and floor marking inside a warehouse

8′ x 10′ modular office at a glance

An 8×10 in-plant office is a complete, factory-built room that assembles inside your warehouse, plant or distribution center on a level slab. It is sold as a system, not a pile of panels: walls, door, window, ceiling and a pre-wired electrical package arrive together, and options are set on your drawing. Here is what an 8×10 is and what it is for.

Item 8′ x 10′ in-plant office
Nominal footprint 8′ x 10′ (80 sq ft)
Typical occupancy 1 person plus a visitor
Best for Single office, shipping office, small QC room
Wall height 8 ft or 9 ft standard
Configuration 4-wall freestanding, or 3-wall using an existing building wall
Wall panels Insulated panels, R-11 to R-19, on a steel or aluminum frame
Sound rating STC 35 standard panel; up to STC 45 assemblies for loud areas
Door Commercial-grade entry door with closer and lockset
Windows Tempered safety glass: fixed, sliding or awning
Ceiling and roof Ceiling standard; load-bearing storage roof optional
Electrical Pre-wired LED lighting, switches and outlets
HVAC Optional wall-mounted heat pump or ducted unit
On-site install Typically 2 to 5 days; single rooms often 2 to 3 days
Price Starting at $8,900 (4-wall kit, before freight and installation). Request a firm quote

Request pricing for an 8×10 office

Prices depend on wall height, panel rating, windows, HVAC and installation conditions, so we quote your actual configuration. Send the size and where it is going, or lay it out yourself in our online configurator first.

Request Pricing Open the Modular Building Configurator Call (800) 326-4403

What fits in an 8×10 office

Illustrative 8' x 10' modular office floor plan showing an example layout: single office

An 8×10 adds the two feet that make a one-person office comfortable. A 30 by 60 inch desk runs along the long wall, the task chair has room to roll back, and a guest chair or a two-drawer file fits on the far side without blocking the door. It is the size most buyers picture when they say “a small office on the floor.”

Orient the 10-foot side toward the work. That gives the longest window run facing the line or dock and keeps the door on the short wall, where it does not cut into the desk area.

Layout tips for an 8×10

  • Run the desk along the 10-foot wall and face the window toward the work area.
  • Put the door on an 8-foot wall so its swing does not overlap the chair.
  • A guest chair and a two-drawer file fit if they share the wall opposite the desk.
  • If drivers or operators come to the office, a transaction window beside the door saves foot traffic inside.
  • Leave one wall without windows for a whiteboard, shelving or a printer stand.

Typical uses for an 8×10 in-plant office

These are the jobs an 8×10 handles well. Each one changes the specification a little, mostly in windows, sound rating and electrical, so tell us the use when you ask for pricing.

📋

Single private office

A manager or engineer gets a door that closes, a full desk and a place for one visitor.

🔍

Shipping and receiving office

Room for a desk, a label printer and a file of carrier paperwork, with a window onto the dock.

🚚

Small QC or inspection room

A bench, a gauge cabinet and stable light and temperature next to the line.

⏰

Scale or weigh office

One operator at a desk with a view of the scale and a window for paperwork.

🔧

Maintenance planner’s office

Work orders, manuals and a terminal kept clean and close to the shop.

What comes standard on an 8×10 modular office

Every in-plant office we supply ships as a complete system. The baseline below is what an 8×10 includes before options. Most of it can be upgraded, and the panel system is the same one used for our larger offices, so an 8×10 can grow later by adding panels.

Inside, walls are vinyl-covered gypsum over an insulated core, with a suspended acoustical ceiling and commercial flooring options. Our wall panels and insulation page explains the panel choices in more detail.

Inside a finished modular office: desk with monitors, glass partition walls and doors to neighboring rooms
  • Insulated wall panels with R-11 to R-19 insulation values, steel or aluminum framing
  • Commercial-grade entry door with closer and lockset
  • Tempered safety glass windows: fixed, sliding or awning
  • Pre-wired electrical with LED lighting, switches and outlets
  • Ceiling panels, with a load-bearing roof deck as an option
  • Vinyl tile or concrete-compatible flooring
  • Powder-coat finish in standard or custom colors
  • Stamped drawings and load data for plan review

3-wall or 4-wall 8×10?

A 4-wall 8×10 stands on its own anywhere on the floor. A 3-wall 8×10 is built against an existing building wall, which then serves as the office’s back wall. A 3-wall layout needs that wall to be reasonably flat and plumb where the panels meet it, and the existing wall’s insulation, condition and fire rating become part of the office. It is a good fit along a quiet exterior or demising wall, and a poor fit against a wall that sweats, vibrates or carries loose utilities.

Options and upgrades for an 8×10

Modular in-plant office with a load-bearing storage roof enclosed by yellow guardrail

Options are where an 8×10 becomes your office instead of a catalog box. The most common changes are wall height, more or larger windows, a better sound rating, HVAC and a roof that can carry storage. Each is set on the drawing before the order is released.

On a small footprint the best upgrades are the ones that make the room work harder: a storage roof adds space without adding floor, and the right door and glazing keep a loud floor outside. For bigger changes, see our two-story modular offices.

Option What it adds When it is worth it on an 8×10
9 ft walls More headroom and room for a taller window When ceiling-mounted HVAC or lighting would feel low, and clear height allows
Extra or larger windows Sight lines to the floor When the person inside supervises an area or watches a dock
Transaction window A pass-through for paperwork Shipping, scale and tool-crib offices
STC 45 assembly Higher sound reduction Next to presses, compressors or a live dock, or for phone-heavy work
Solid-core gasketed door and insulated glazing Seals the openings Any time you upgrade the wall panel for sound
Wall-mounted heat pump or ducted HVAC Heating and cooling Unconditioned buildings, hot roofs and cold docks
Load-bearing storage roof Storage on top of the office When floor space is tight and the roof can be reached safely
1-hour or 2-hour fire-rated walls Fire separation Where occupancy, separation or location requires it
Interior partition A second room Larger sizes that need an office plus storage
Dedicated circuits and data drops Power for equipment and network Printers, test equipment, servers and appliances

Electrical, HVAC and sound for an 8×10

Pre-wired panels arrive with lighting, switching and outlets in place. What needs planning is the feed to the office, network drops and any dedicated circuits for equipment inside. Tell us the equipment list when you ask for pricing so the electrical is sized right the first time. The final connection is made and inspected by a licensed electrician under your local code. More detail is on our modular building electrical page.

The usual choice is a wall-mounted heat pump that heats and cools from one unit. Mount it on a wall that does not carry the main window. If the office sits by a dock door, ask about supplemental heat; a small office loses heat quickly every time a trailer pulls out. See modular building HVAC options for the unit types.

Aluminum binder post between modular wall panels with the cover off, showing a factory electrical box
Environment around the office Recommended rating Notes
Quiet warehouse or parts room STC 35 Standard insulated panel is adequate
General distribution floor STC 38 to 42 Add a gasketed door and insulated glazing
Next to presses or compressors STC 45 Upgraded panel plus sealed openings
Quality lab or phone-heavy office STC 45 Specify a solid-core door and dual glazing

Planning an 8×10 office inside your building

Plant room entrance protected by yellow steel guardrail, a railed pedestrian walkway and bollards

A small office is quick to install, but the same site questions apply as on a big one. Most delays come from discovering a problem on install day, not from the office itself.

If the office sits near forklift traffic, protect the walls and especially the door landing. Our guide to forklift protection for in-plant offices covers guardrail, bollards and walkways.

  • Clear height: plan for roughly 10 to 12 feet of clear height above the floor for a single-story office once the roof panel, any HVAC unit and sprinkler clearance are counted.
  • Sprinklers: a roofed office inside a sprinklered building usually needs heads inside it. That is your fire protection contractor’s scope; budget it early.
  • Slab: a clear, level slab in the footprint; forklift access to bring panels in.
  • Power and data: decide where the feed comes from and where network drops land.
  • Permits: most jurisdictions require a permit and plan review for an occupied office with permanent power. We provide stamped drawings and load data. See permits and code compliance.
  • Fire rating: 1-hour and 2-hour assemblies are available where code requires them. See fire-rated in-plant offices.
  • Egress and access: An 8×10 is a single-occupant office in almost every layout, so one standard door is the norm. If the office has to be accessible, keep a clear 60-inch turning space and a clear approach to the door hardware; on an 8×10 that means the furniture lives on the walls.

Lead time and installation

Our in-plant office projects typically run on 4 to 8 week lead times from approved drawings, with standard configurations usually at the shorter end. Fabrication and freight take most of that time; glazing, fire rating and finish choices can add to it. Our modular building lead times page explains what moves the schedule.

On site, a single-room office like an 8×10 typically assembles in two to three days, and most in-plant offices are complete and occupied in two to five days. Crews set the floor track, stand the panels, hang the door and glazing, set the HVAC and land power, with very little cutting and no drywall dust in a running operation.

Finished single-story white modular office with a door and a long row of windows in a warehouse
1

Define the space

Use, headcount, noise level, equipment inside and how long the 8×10 will stay where it is going.

2

Design and approve

Layout, panel and STC rating, windows, HVAC, electrical load, fire rating and finish confirmed on drawings.

3

Prepare the site

Slab checked, power feed located, sprinkler and lighting clearance verified, work window scheduled.

4

Assemble and commission

Panels, door, windows, HVAC and power installed; the office is ready to occupy.

8′ x 10′ modular office pricing

An 8×10 modular in-plant office starts at $8,900 for a basic 4-wall kit: one windowed entry door, lighting, outlets, a steel roof deck and a drop ceiling. That is before freight, installation and tax, and your final price is confirmed by quote. Popular options add to the base kit: windows typically run about $400 to $600 each, a wall-mounted HVAC unit about $2,200 to $4,100, and pre-wired electrical about $1,000 to $1,600. Installation is quoted per project because it depends on your site. These are the items that move the price most:

  • Wall height (8 ft or 9 ft) and 3-wall versus 4-wall construction
  • Panel insulation and sound rating, plus the matching door and glazing
  • Number and size of windows, and any transaction window
  • HVAC type, and whether the office needs supplemental heat near a dock
  • Electrical scope: dedicated circuits, data drops and appliance loads
  • Fire-rated walls, a storage roof or an interior partition
  • Installation conditions: slab, access, working hours and sprinkler work by others

For a sense of how modular compares with building the same room in drywall, see our modular office vs conventional buildout comparison and the in-plant modular office buying guide.

Get a price on your 8×10

Tell us the size, the use and where it is going in the building. We will return a configuration, drawings and a firm price, typically within a few business days.

Request Pricing Design It Online Call (800) 326-4403

How the 8×10 compares with other standard sizes

Going down to an 8×8 saves two feet but loses the guest chair. Going up to a 10×10 adds 20 square feet, enough for a second small desk or a bookcase and two visitor chairs. If the office will ever hold two people at desks, skip ahead and look at the 10×12 or 12×12.

Size Floor area Typical occupancy Best for
8′ x 8′ 64 sq ft 1 person at a desk or counter Supervisor station, QC check point, dispatch desk
8′ x 10′ (this page) 80 sq ft 1 person plus a visitor Single office, shipping office, small QC room
10′ x 10′ 100 sq ft 1 to 2 people Private office, dispatch, wellness or first-aid room
10′ x 12′ 120 sq ft 1 to 2 people Supervisor office, manager office, two-desk office
12′ x 12′ 144 sq ft 2 people at desks, or 4 to 6 seated Two-person office, QC room, small meeting room
12′ x 16′ 192 sq ft 2 to 3 at desks, or 6 to 8 seated Break room, meeting room, multi-desk office

Other standard in-plant office sizes

Example floor plan of a 8' x 8' modular office8′ x 8′ Modular Office64 sq ft. Supervisor station, QC check point, dispatch desk.
Example floor plan of a 10' x 10' modular office10′ x 10′ Modular Office100 sq ft. Private office, dispatch, wellness or first-aid room.
Example floor plan of a 10' x 12' modular office10′ x 12′ Modular Office120 sq ft. Supervisor office, manager office, two-desk office.
Example floor plan of a 12' x 12' modular office12′ x 12′ Modular Office144 sq ft. Two-person office, QC room, small meeting room.
Example floor plan of a 12' x 16' modular office12′ x 16′ Modular Office192 sq ft. Break room, meeting room, multi-desk office.

Need a different size or several rooms? Every size is configurable, from 8×8 up to large multi-room layouts. Start on the main modular in-plant offices page, read our in-plant office design guide, or browse all in-plant and industrial modular buildings.

8′ x 10′ modular office FAQ

What is the difference between a 3-wall and a 4-wall 8×10 office?
A 4-wall office stands on its own. A 3-wall office uses an existing building wall as its back wall, so one side of panels is left out. A 3-wall layout needs a wall that is reasonably flat and plumb where the panels meet it, and the existing wall’s insulation and fire rating become part of the office.
What comes standard with an 8×10 modular office?
A complete system rather than loose walls: insulated wall panels on a steel or aluminum frame, a commercial-grade entry door with closer and lockset, tempered safety glass windows, pre-wired lighting, switches and outlets, and a ceiling. HVAC, fire-rated walls and a load-bearing roof are configured on your drawing.
Is 8×10 big enough for two people?
Only for short periods. Two desks do not fit comfortably in 80 square feet with a door swing. For two people working full shifts, a 10×12 or 12×12 is the practical minimum.
How long does it take to get an 8×10 modular office?
Our in-plant office projects typically run on 4 to 8 week lead times from approved drawings, with standard configurations usually at the shorter end. On site, a single room like an 8×10 typically assembles in two to three days.
How much does an 8×10 modular office cost?
A basic 4-wall 8×10 kit starts at $8,900, before freight, installation and tax. Windows, HVAC, pre-wired electrical, wall height and panel rating add to that, and installation is quoted per project. Request pricing with your size and use, or lay out the office in our modular building configurator first.
Do I need a permit for an 8×10 in-plant office?
Usually, yes. An occupied office connected to permanent power is reviewed by most building departments. We provide stamped drawings, load data and specifications for the submittal. A roofed office in a sprinklered building often needs sprinkler heads inside, which your fire protection contractor determines.

Ready to price an 8×10 in-plant office?

Send the size, the use and a photo of the spot. We will come back with a layout, drawings and a firm price.

Headquartered in Salt Lake City, UT • Serving customers nationwide
Local service areas: Salt Lake City • Provo • Ogden • Park City • St. George • Logan • Lehi • Orem